PDD examples · Pharma
Process definition document (PDD) template

Adverse event case processing (pharmacovigilance): PDD template and example

This is a complete process definition document (PDD) for adverse event case processing, also called individual case safety report (ICSR) handling, safety case intake or pharmacovigilance case management. It describes how a marketing authorisation holder turns a raw report of a suspected adverse reaction into a coded, assessed and submitted case: from the first email, call or literature hit to the archived case file. The company is fictional, but the roles, systems and checkpoints are those of a typical pharmacovigilance department.

Use it as a starting point. Replace the company details, keep the sections, and walk through each step with the case processors, safety physicians and the quality contact who run it. Most departments change the intake channels, the triage rules for non-serious cases and the follow-up schedule. Signal detection, aggregate reports, risk management plans and literature search strategy need their own documents. Reporting timelines differ by country and report type, so every deadline in this document must be checked against the regulations that apply to your products. The template describes a process. It does not make an organisation compliant.

1. Purpose and scope

This procedure describes how the pharmacovigilance department of Brennholt Pharma AB processes individual adverse event cases, from the moment any employee, partner, healthcare professional, patient or literature search delivers a report, to the moment the case is submitted to the authorities that require it and the case file is archived. It gives the safety team, the medical reviewers, the affiliates and the quality function one shared description of who does what and by when, so that no report is lost, every case is assessed consistently and submissions leave inside the reporting clock.

In scope

  • Case intake from every source: direct reports, affiliates, partners, literature, regulatory authority databases and solicited programmes
  • Duplicate check and validity check of the four minimum criteria
  • Data entry, coding and narrative writing in the safety database
  • Seriousness, causality and expectedness assessment
  • Medical review, follow-up requests and case versioning
  • Submission of cases to authorities and partners within the applicable reporting clock
  • Archiving of the case and its source documents

Out of scope

  • Signal detection and signal evaluation
  • Periodic safety update reports and other aggregate reports
  • Risk management plan maintenance
  • Literature search strategy and screening
  • Product quality complaints that carry no adverse event

2. Process at a glance

Trigger
Any employee, partner, healthcare professional, patient or literature search delivers information about a suspected adverse reaction linked to one of the company's products.
Starts when
The Case Intake Coordinator registers the source document in the safety inbox tracker and stamps the day of first receipt.
Ends when
The final case version is submitted to the required recipients, the acknowledgement is stored and the case file is archived.
Volume
About 9,800 incoming reports a year, of which about 6,400 become valid cases and about 2,100 are serious
Working hours
Monday to Friday 08:00 to 17:00 CET. A duty processor covers the safety inbox at weekends for serious reports, and the clock for any case starts on the day of first receipt by any employee, not the next working day.
Company in this example
Brennholt Pharma AB, a mid-sized marketing authorisation holder in Uppsala, Sweden (about 260 employees, 14 products on the market in 22 countries)
Inputs
Source document (email, form, call note, literature article, partner report), Product and licence information, Safety database dictionaries and coding conventions, Reporting rules by country and report type, Follow-up responses from reporters
Outputs
Registered and triaged intake record, Valid or invalid case decision, Coded case with narrative, Assessment of seriousness, causality and expectedness, Medically reviewed case, Submitted case with authority acknowledgement, Archived case file

3. Roles and responsibilities

Case Intake Coordinator
Monitors the safety inbox and hotline, registers every source document, stamps the receipt date, triages by seriousness and sends obvious non-cases back to the sender.
Case Processor
Searches for duplicates, checks the four minimum criteria, enters and codes the case, writes the narrative, requests follow-up and prepares the case for review.
Safety Physician
Confirms seriousness, reviews causality and expectedness against the reference safety information, edits the company comment and approves the case for submission.
Regulatory Submissions Specialist
Applies the reporting rules, schedules and sends submissions to authorities and partners, monitors acknowledgements and handles rejected transmissions.
Quality Contact
Samples cases for quality review, tracks compliance with the reporting clock, logs deviations and supports audits and inspections.
Affiliate Safety Representative (external)
Receives reports in the local language, forwards them to the central team within the agreed time and answers follow-up questions in the country.
Reporter (external)
A healthcare professional, patient or partner who supplied the report and who may be asked for more information.

4. Systems

  • Argus Safety: safety database for cases, coding, assessment and submissions
  • MedDRA and WHODrug dictionaries, loaded in the safety database
  • Shared safety mailbox and 24-hour hotline
  • Veeva Vault QMS: deviations and quality review records
  • EudraVigilance gateway and national authority portals
  • SharePoint: intake tracker, reference safety information and archive index

5. Process map

Process diagram goes here

Draw your own swimlane: one lane per role from section 3, the steps from section 6 in order, and a diamond for each decision in section 7. Your process will differ from this example, so map it from what your team actually does.

6. Procedure, step by step

#StepWhoWhat happensSystemOutput
1Register the source documentCase Intake CoordinatorLogs each report that arrives by email, form, call or partner exchange, records the sender, product and channel, and stamps the date the company first received it. Reports that reach other departments are forwarded the same day, and the date of first receipt by any employee is kept.SharePoint intake tracker, safety mailboxIntake record with day zero
2Triage by seriousness and urgencyCase Intake CoordinatorReads the report and flags anything that may be serious, involves death, a pregnancy or a product of special interest. Flagged reports go to the front of the queue and to the duty processor the same day. This takes 5 to 10 minutes.SharePoint intake trackerPriority flag, queue position
3Screen out non-casesCase Intake CoordinatorIf the report carries no product of the company, no suspected reaction or only a general enquiry (about 18% of intake), sends it to the right department and closes the record with a reason. Everything else moves on to case processing.SharePoint intake trackerClosed non-case, or case for processing
4Search for duplicatesCase ProcessorSearches the database on patient initials or reference, age, sex, product, event and reporter. If a match is found (about 11% of reports), the new information is added to the existing case as a follow-up version rather than opened as a new case. This takes 5 to 15 minutes.Argus SafetyNew case, or follow-up to an existing case
5Check the four minimum criteriaCase ProcessorConfirms that the report names an identifiable reporter, an identifiable patient, a suspect product and a suspected reaction. If a criterion is missing (about 9% of reports), the case is kept open as invalid, the reporter is asked for the missing item and the clock starts when the fourth criterion is met.Argus SafetyValid case, or invalid case awaiting information
6Enter the case dataCase ProcessorEnters reporter, patient, product, dosing, event dates, outcome, medical history and concomitant medicines in the structured fields. Data are copied from the source and are not interpreted. This takes 25 to 45 minutes for a standard case.Argus SafetyEntered case
7Code events, products and historyCase ProcessorCodes the reported terms to the current MedDRA version and the products to the drug dictionary, using the department's coding conventions. Terms that cannot be coded unambiguously are marked for the medical reviewer.Argus Safety, MedDRA, WHODrugCoded case
8Write the narrativeCase ProcessorWrites a chronological narrative in plain language that matches the structured data: what happened, when, what treatment was given and what the outcome was. A second processor reads complex narratives. This takes 10 to 20 minutes.Argus SafetyCase narrative
9Assess seriousness and expectednessCase ProcessorProposes seriousness criteria and compares each event with the reference safety information in force, marking it as listed or unlisted. The proposal is not final until the safety physician confirms it.Argus Safety, reference safety informationProposed seriousness and expectedness
10Perform the medical reviewSafety PhysicianConfirms or changes the seriousness, adds the causality assessment, checks coding and narrative against the source and writes the company comment. Serious cases are reviewed within 1 working day, non-serious cases within 3. If the case needs more information, it returns to the processor.Argus SafetyMedically reviewed case, or request for information
11Request follow-up informationCase ProcessorFor cases that are serious or of special interest, sends a targeted follow-up request through the affiliate or directly to the reporter, usually with a first reminder after 7 days and a second after 14 days. Each attempt is logged in the case. Non-serious cases get one request, if any.Email, Argus SafetyFollow-up request sent, attempts logged
12Answer the follow-up requestReporterSupplies outcome, dates, test results or product details. About 45% of requests are answered, and many arrive after the first submission. New information is processed as a new version of the case.Email, phoneFollow-up information, or no response
13Determine reporting rulesRegulatory Submissions SpecialistApplies the reporting matrix to the case: which authorities and partners receive it, which timeline applies and what the due date is. The matrix lists the rules by country, report type and product and is checked against the applicable regulations at least every year and after every legislative change.Argus Safety, SharePoint reporting matrixReporting schedule with due dates
14Approve the case for submissionSafety PhysicianLocks the final version after confirming that all open questions are answered or documented. No case leaves the database without this approval.Argus SafetyApproved and locked case version
15Submit to authorities and partnersRegulatory Submissions SpecialistGenerates the electronic report and transmits it before the due date. Cases that cannot be sent electronically are sent by the route the authority accepts and the route is recorded.Argus Safety, EudraVigilance gateway, national portalsTransmitted report
16Check acknowledgements and rejectionsRegulatory Submissions SpecialistChecks that each transmission was acknowledged. Rejected reports (about 3%) are corrected the same day and resent, and the new date is recorded with the reason. Otherwise the acknowledgement is attached to the case.Argus Safety, EudraVigilance gatewayAcknowledgement stored, or corrected resubmission
17Sample cases for quality reviewQuality ContactReviews a sample of cases each month, with every case that was submitted late reviewed in full. Errors in coding, dates or narrative are logged and sent to the case processor as a correction. A late submission opens a deviation with a cause.Argus Safety, Veeva Vault QMSQuality review result, deviation if needed
18Archive the case fileCase ProcessorStores the source documents, the correspondence with the reporter, the acknowledgements and the audit trail with the case and links them in the archive index. The case file stays retrievable for the period required for the product.Argus Safety, SharePoint archiveArchived case file

7. Decision points and business rules

  • Is the report about a product of the company with a suspected reaction? No (about 18% of intake): route it to the right department and close the record (step 3).
  • Is there already a case for this patient and event? Yes (about 11% of reports): add the information as a follow-up version (step 4).
  • Are all four minimum criteria met? No (about 9% of reports): keep the case invalid and ask the reporter for the missing item (step 5).
  • Is the event serious or of special interest? Yes (about 32% of valid cases): the case moves to the front of the queue and is reviewed within 1 working day (steps 2 and 10).
  • Is the event listed in the reference safety information? No: it is unexpected, and the reporting rules for unexpected serious cases apply (steps 9 and 13).
  • Does the case need more information before it can be assessed? Yes: a follow-up request goes to the reporter (steps 10 and 11).
  • Was the transmission acknowledged? No (about 3%): correct and resend the same day (step 16).

8. Exceptions

  • A report arrives on a Friday evening through a partner (a few per month): the duty processor registers it over the weekend so that the clock is not lost.
  • A report reaches a sales representative or another employee instead of the safety inbox: the employee forwards it the same day, and day zero is the day that employee received it.
  • A literature article describes several patients: one case is opened per identifiable patient, all sharing the same source.
  • The reporter cannot be reached after the planned attempts: the case is closed with the attempts documented and is submitted with the information available.
  • The safety database is unavailable: the intake coordinator keeps the paper log and the cases are entered with the original receipt date once the system returns.

9. Controls

  • Every report is registered with its date of first receipt, and the date is never changed after the fact.
  • The processor who enters a case cannot approve it for submission. The safety physician approves every final version.
  • The reporting matrix is checked against the applicable regulations at least once a year, and every change is recorded.
  • Late submissions are reviewed individually and each opens a deviation with a cause and an action.
  • The safety database keeps an audit trail of every change. Coding versions are updated on a fixed schedule and the update is documented.
  • Contracts with partners and affiliates state how fast they forward reports, and the forwarding time is measured.
  • Case files are archived with source documents and acknowledgements so that any case can be retrieved during an inspection.

10. Known issues today

  • Reports sit in individual inboxes of sales and medical staff before they reach the safety team, which shortens the time left in the clock.
  • Duplicates are found late because partners send the same report with different references.
  • Processors retype data from PDFs and call notes, and typing mistakes surface only at medical review.
  • Follow-up responses arrive after submission and are processed in the wrong order, which creates version confusion.
  • The reporting matrix lives in a spreadsheet that few people can interpret, so due dates are sometimes set manually.

11. RACI matrix

R = responsible (does the work), A = accountable (owns the outcome), C = consulted, I = informed.

ActivityIntake CoordinatorCase ProcessorSafety PhysicianSubmissionsQuality Contact
Register and triage incoming reportsA/RCI
Check duplicates and validityIA/RC
Enter, code and write the narrativeA/RCI
Assess seriousness and expectednessRA
Medical reviewCA/R
Follow-up requestsIA/RC
Submit and check acknowledgementsICA/RI
Quality review and deviationsCCCA/R
Archive the case fileA/RII

12. KPIs

Timely submission rate
Share of cases submitted on or before the due date set by the applicable reporting rules. The target is 100% for serious cases and at least 98% overall.
Intake to registration time
Working hours from a report reaching the company to the intake coordinator registering it. The target is under 4 working hours.
Medical review turnaround
Average working days from a case being ready for review to the safety physician approving it, split by serious and non-serious cases.
Follow-up response rate
Share of follow-up requests that receive an answer, measured per source type. It shows which channels are worth chasing.
Case quality error rate
Share of sampled cases with a coding, date or narrative error found in quality review. The target is under 3%.
Rejected transmissions
Share of submitted reports that the authority gateway rejected on first attempt.

How to adapt this template

  • Replace the company, the safety database and the list of recipients with yours. If you outsource case processing to a partner, add the partner as a role and make the handover steps explicit.
  • Check every timeline against the regulations that apply to your products and markets, and write the due dates into the reporting matrix. The numbers in this document are placeholders for the review times, not regulatory claims.
  • Decide how non-serious cases from literature or solicited programmes are handled. Some departments use a simplified path with lighter review.
  • Set your own follow-up schedule, number of attempts and wording by report type. The 7 and 14 day reminders are an example.
  • Check the percentages with real data. A month of intake normally shows the true share of duplicates, invalid cases and rejections.
  • Keep the as-is version after you redesign the process. It is your baseline for measuring the change.

Questions people ask

What is a PDD for adverse event case processing?

A process definition document that describes how a suspected adverse reaction report becomes a coded, assessed and submitted case: who registers it, who enters it, who reviews it and who sends it, in which system and under which rules. It is used to align the safety team, train new processors and find where cases wait.

What are the four minimum criteria for a valid case?

An identifiable reporter, an identifiable patient, at least one suspect product and at least one suspected reaction. If one is missing, the case is not yet valid for reporting and the team must ask for it. The details of what counts as identifiable are set in the applicable guidance and should be written into your procedure.

When does the reporting clock start?

In general terms, it starts on the day any employee or contracted partner first receives information that meets the minimum criteria. This is why an intake record with the exact first receipt date matters. The length of the clock depends on seriousness, expectedness and country, so check it against the regulation that applies.

What is the difference between seriousness and expectedness?

Seriousness describes the outcome, for example death, hospitalisation or a persistent disability. Expectedness describes whether the event is already listed in the reference safety information for the product. A serious and unexpected case usually has the strictest reporting rule.

How do I deal with duplicates?

Search on the data that identify the case, not on the reporter's reference alone, because partners and affiliates often use their own. If a match is found, add the new information as a follow-up version and keep a link to both sources. Document the matching rules so that processors apply them the same way.

Can I use this template for free?

Yes. Download it in Word or PDF and adapt it to your company. The company in the example is fictional.

Map your own version of this process.

Upload your SOP or describe the process. Processfix builds the map, simulates it and shows where the time goes. People review the results and decide.