Adverse event case processing (pharmacovigilance): PDD template and example
This is a complete process definition document (PDD) for adverse event case processing, also called individual case safety report (ICSR) handling, safety case intake or pharmacovigilance case management. It describes how a marketing authorisation holder turns a raw report of a suspected adverse reaction into a coded, assessed and submitted case: from the first email, call or literature hit to the archived case file. The company is fictional, but the roles, systems and checkpoints are those of a typical pharmacovigilance department.
Use it as a starting point. Replace the company details, keep the sections, and walk through each step with the case processors, safety physicians and the quality contact who run it. Most departments change the intake channels, the triage rules for non-serious cases and the follow-up schedule. Signal detection, aggregate reports, risk management plans and literature search strategy need their own documents. Reporting timelines differ by country and report type, so every deadline in this document must be checked against the regulations that apply to your products. The template describes a process. It does not make an organisation compliant.
1. Purpose and scope
This procedure describes how the pharmacovigilance department of Brennholt Pharma AB processes individual adverse event cases, from the moment any employee, partner, healthcare professional, patient or literature search delivers a report, to the moment the case is submitted to the authorities that require it and the case file is archived. It gives the safety team, the medical reviewers, the affiliates and the quality function one shared description of who does what and by when, so that no report is lost, every case is assessed consistently and submissions leave inside the reporting clock.
In scope
- Case intake from every source: direct reports, affiliates, partners, literature, regulatory authority databases and solicited programmes
- Duplicate check and validity check of the four minimum criteria
- Data entry, coding and narrative writing in the safety database
- Seriousness, causality and expectedness assessment
- Medical review, follow-up requests and case versioning
- Submission of cases to authorities and partners within the applicable reporting clock
- Archiving of the case and its source documents
Out of scope
- Signal detection and signal evaluation
- Periodic safety update reports and other aggregate reports
- Risk management plan maintenance
- Literature search strategy and screening
- Product quality complaints that carry no adverse event
2. Process at a glance
- Trigger
- Any employee, partner, healthcare professional, patient or literature search delivers information about a suspected adverse reaction linked to one of the company's products.
- Starts when
- The Case Intake Coordinator registers the source document in the safety inbox tracker and stamps the day of first receipt.
- Ends when
- The final case version is submitted to the required recipients, the acknowledgement is stored and the case file is archived.
- Volume
- About 9,800 incoming reports a year, of which about 6,400 become valid cases and about 2,100 are serious
- Working hours
- Monday to Friday 08:00 to 17:00 CET. A duty processor covers the safety inbox at weekends for serious reports, and the clock for any case starts on the day of first receipt by any employee, not the next working day.
- Company in this example
- Brennholt Pharma AB, a mid-sized marketing authorisation holder in Uppsala, Sweden (about 260 employees, 14 products on the market in 22 countries)
- Inputs
- Source document (email, form, call note, literature article, partner report), Product and licence information, Safety database dictionaries and coding conventions, Reporting rules by country and report type, Follow-up responses from reporters
- Outputs
- Registered and triaged intake record, Valid or invalid case decision, Coded case with narrative, Assessment of seriousness, causality and expectedness, Medically reviewed case, Submitted case with authority acknowledgement, Archived case file
3. Roles and responsibilities
- Case Intake Coordinator
- Monitors the safety inbox and hotline, registers every source document, stamps the receipt date, triages by seriousness and sends obvious non-cases back to the sender.
- Case Processor
- Searches for duplicates, checks the four minimum criteria, enters and codes the case, writes the narrative, requests follow-up and prepares the case for review.
- Safety Physician
- Confirms seriousness, reviews causality and expectedness against the reference safety information, edits the company comment and approves the case for submission.
- Regulatory Submissions Specialist
- Applies the reporting rules, schedules and sends submissions to authorities and partners, monitors acknowledgements and handles rejected transmissions.
- Quality Contact
- Samples cases for quality review, tracks compliance with the reporting clock, logs deviations and supports audits and inspections.
- Affiliate Safety Representative (external)
- Receives reports in the local language, forwards them to the central team within the agreed time and answers follow-up questions in the country.
- Reporter (external)
- A healthcare professional, patient or partner who supplied the report and who may be asked for more information.
4. Systems
- Argus Safety: safety database for cases, coding, assessment and submissions
- MedDRA and WHODrug dictionaries, loaded in the safety database
- Shared safety mailbox and 24-hour hotline
- Veeva Vault QMS: deviations and quality review records
- EudraVigilance gateway and national authority portals
- SharePoint: intake tracker, reference safety information and archive index
5. Process map
Draw your own swimlane: one lane per role from section 3, the steps from section 6 in order, and a diamond for each decision in section 7. Your process will differ from this example, so map it from what your team actually does.
6. Procedure, step by step
| # | Step | Who | What happens | System | Output |
|---|---|---|---|---|---|
| 1 | Register the source document | Case Intake Coordinator | Logs each report that arrives by email, form, call or partner exchange, records the sender, product and channel, and stamps the date the company first received it. Reports that reach other departments are forwarded the same day, and the date of first receipt by any employee is kept. | SharePoint intake tracker, safety mailbox | Intake record with day zero |
| 2 | Triage by seriousness and urgency | Case Intake Coordinator | Reads the report and flags anything that may be serious, involves death, a pregnancy or a product of special interest. Flagged reports go to the front of the queue and to the duty processor the same day. This takes 5 to 10 minutes. | SharePoint intake tracker | Priority flag, queue position |
| 3 | Screen out non-cases | Case Intake Coordinator | If the report carries no product of the company, no suspected reaction or only a general enquiry (about 18% of intake), sends it to the right department and closes the record with a reason. Everything else moves on to case processing. | SharePoint intake tracker | Closed non-case, or case for processing |
| 4 | Search for duplicates | Case Processor | Searches the database on patient initials or reference, age, sex, product, event and reporter. If a match is found (about 11% of reports), the new information is added to the existing case as a follow-up version rather than opened as a new case. This takes 5 to 15 minutes. | Argus Safety | New case, or follow-up to an existing case |
| 5 | Check the four minimum criteria | Case Processor | Confirms that the report names an identifiable reporter, an identifiable patient, a suspect product and a suspected reaction. If a criterion is missing (about 9% of reports), the case is kept open as invalid, the reporter is asked for the missing item and the clock starts when the fourth criterion is met. | Argus Safety | Valid case, or invalid case awaiting information |
| 6 | Enter the case data | Case Processor | Enters reporter, patient, product, dosing, event dates, outcome, medical history and concomitant medicines in the structured fields. Data are copied from the source and are not interpreted. This takes 25 to 45 minutes for a standard case. | Argus Safety | Entered case |
| 7 | Code events, products and history | Case Processor | Codes the reported terms to the current MedDRA version and the products to the drug dictionary, using the department's coding conventions. Terms that cannot be coded unambiguously are marked for the medical reviewer. | Argus Safety, MedDRA, WHODrug | Coded case |
| 8 | Write the narrative | Case Processor | Writes a chronological narrative in plain language that matches the structured data: what happened, when, what treatment was given and what the outcome was. A second processor reads complex narratives. This takes 10 to 20 minutes. | Argus Safety | Case narrative |
| 9 | Assess seriousness and expectedness | Case Processor | Proposes seriousness criteria and compares each event with the reference safety information in force, marking it as listed or unlisted. The proposal is not final until the safety physician confirms it. | Argus Safety, reference safety information | Proposed seriousness and expectedness |
| 10 | Perform the medical review | Safety Physician | Confirms or changes the seriousness, adds the causality assessment, checks coding and narrative against the source and writes the company comment. Serious cases are reviewed within 1 working day, non-serious cases within 3. If the case needs more information, it returns to the processor. | Argus Safety | Medically reviewed case, or request for information |
| 11 | Request follow-up information | Case Processor | For cases that are serious or of special interest, sends a targeted follow-up request through the affiliate or directly to the reporter, usually with a first reminder after 7 days and a second after 14 days. Each attempt is logged in the case. Non-serious cases get one request, if any. | Email, Argus Safety | Follow-up request sent, attempts logged |
| 12 | Answer the follow-up request | Reporter | Supplies outcome, dates, test results or product details. About 45% of requests are answered, and many arrive after the first submission. New information is processed as a new version of the case. | Email, phone | Follow-up information, or no response |
| 13 | Determine reporting rules | Regulatory Submissions Specialist | Applies the reporting matrix to the case: which authorities and partners receive it, which timeline applies and what the due date is. The matrix lists the rules by country, report type and product and is checked against the applicable regulations at least every year and after every legislative change. | Argus Safety, SharePoint reporting matrix | Reporting schedule with due dates |
| 14 | Approve the case for submission | Safety Physician | Locks the final version after confirming that all open questions are answered or documented. No case leaves the database without this approval. | Argus Safety | Approved and locked case version |
| 15 | Submit to authorities and partners | Regulatory Submissions Specialist | Generates the electronic report and transmits it before the due date. Cases that cannot be sent electronically are sent by the route the authority accepts and the route is recorded. | Argus Safety, EudraVigilance gateway, national portals | Transmitted report |
| 16 | Check acknowledgements and rejections | Regulatory Submissions Specialist | Checks that each transmission was acknowledged. Rejected reports (about 3%) are corrected the same day and resent, and the new date is recorded with the reason. Otherwise the acknowledgement is attached to the case. | Argus Safety, EudraVigilance gateway | Acknowledgement stored, or corrected resubmission |
| 17 | Sample cases for quality review | Quality Contact | Reviews a sample of cases each month, with every case that was submitted late reviewed in full. Errors in coding, dates or narrative are logged and sent to the case processor as a correction. A late submission opens a deviation with a cause. | Argus Safety, Veeva Vault QMS | Quality review result, deviation if needed |
| 18 | Archive the case file | Case Processor | Stores the source documents, the correspondence with the reporter, the acknowledgements and the audit trail with the case and links them in the archive index. The case file stays retrievable for the period required for the product. | Argus Safety, SharePoint archive | Archived case file |
7. Decision points and business rules
- Is the report about a product of the company with a suspected reaction? No (about 18% of intake): route it to the right department and close the record (step 3).
- Is there already a case for this patient and event? Yes (about 11% of reports): add the information as a follow-up version (step 4).
- Are all four minimum criteria met? No (about 9% of reports): keep the case invalid and ask the reporter for the missing item (step 5).
- Is the event serious or of special interest? Yes (about 32% of valid cases): the case moves to the front of the queue and is reviewed within 1 working day (steps 2 and 10).
- Is the event listed in the reference safety information? No: it is unexpected, and the reporting rules for unexpected serious cases apply (steps 9 and 13).
- Does the case need more information before it can be assessed? Yes: a follow-up request goes to the reporter (steps 10 and 11).
- Was the transmission acknowledged? No (about 3%): correct and resend the same day (step 16).
8. Exceptions
- A report arrives on a Friday evening through a partner (a few per month): the duty processor registers it over the weekend so that the clock is not lost.
- A report reaches a sales representative or another employee instead of the safety inbox: the employee forwards it the same day, and day zero is the day that employee received it.
- A literature article describes several patients: one case is opened per identifiable patient, all sharing the same source.
- The reporter cannot be reached after the planned attempts: the case is closed with the attempts documented and is submitted with the information available.
- The safety database is unavailable: the intake coordinator keeps the paper log and the cases are entered with the original receipt date once the system returns.
9. Controls
- Every report is registered with its date of first receipt, and the date is never changed after the fact.
- The processor who enters a case cannot approve it for submission. The safety physician approves every final version.
- The reporting matrix is checked against the applicable regulations at least once a year, and every change is recorded.
- Late submissions are reviewed individually and each opens a deviation with a cause and an action.
- The safety database keeps an audit trail of every change. Coding versions are updated on a fixed schedule and the update is documented.
- Contracts with partners and affiliates state how fast they forward reports, and the forwarding time is measured.
- Case files are archived with source documents and acknowledgements so that any case can be retrieved during an inspection.
10. Known issues today
- Reports sit in individual inboxes of sales and medical staff before they reach the safety team, which shortens the time left in the clock.
- Duplicates are found late because partners send the same report with different references.
- Processors retype data from PDFs and call notes, and typing mistakes surface only at medical review.
- Follow-up responses arrive after submission and are processed in the wrong order, which creates version confusion.
- The reporting matrix lives in a spreadsheet that few people can interpret, so due dates are sometimes set manually.
11. RACI matrix
R = responsible (does the work), A = accountable (owns the outcome), C = consulted, I = informed.
| Activity | Intake Coordinator | Case Processor | Safety Physician | Submissions | Quality Contact |
|---|---|---|---|---|---|
| Register and triage incoming reports | A/R | C | I | ||
| Check duplicates and validity | I | A/R | C | ||
| Enter, code and write the narrative | A/R | C | I | ||
| Assess seriousness and expectedness | R | A | |||
| Medical review | C | A/R | |||
| Follow-up requests | I | A/R | C | ||
| Submit and check acknowledgements | I | C | A/R | I | |
| Quality review and deviations | C | C | C | A/R | |
| Archive the case file | A/R | I | I |
12. KPIs
- Timely submission rate
- Share of cases submitted on or before the due date set by the applicable reporting rules. The target is 100% for serious cases and at least 98% overall.
- Intake to registration time
- Working hours from a report reaching the company to the intake coordinator registering it. The target is under 4 working hours.
- Medical review turnaround
- Average working days from a case being ready for review to the safety physician approving it, split by serious and non-serious cases.
- Follow-up response rate
- Share of follow-up requests that receive an answer, measured per source type. It shows which channels are worth chasing.
- Case quality error rate
- Share of sampled cases with a coding, date or narrative error found in quality review. The target is under 3%.
- Rejected transmissions
- Share of submitted reports that the authority gateway rejected on first attempt.
How to adapt this template
- Replace the company, the safety database and the list of recipients with yours. If you outsource case processing to a partner, add the partner as a role and make the handover steps explicit.
- Check every timeline against the regulations that apply to your products and markets, and write the due dates into the reporting matrix. The numbers in this document are placeholders for the review times, not regulatory claims.
- Decide how non-serious cases from literature or solicited programmes are handled. Some departments use a simplified path with lighter review.
- Set your own follow-up schedule, number of attempts and wording by report type. The 7 and 14 day reminders are an example.
- Check the percentages with real data. A month of intake normally shows the true share of duplicates, invalid cases and rejections.
- Keep the as-is version after you redesign the process. It is your baseline for measuring the change.
Questions people ask
What is a PDD for adverse event case processing?
A process definition document that describes how a suspected adverse reaction report becomes a coded, assessed and submitted case: who registers it, who enters it, who reviews it and who sends it, in which system and under which rules. It is used to align the safety team, train new processors and find where cases wait.
What are the four minimum criteria for a valid case?
An identifiable reporter, an identifiable patient, at least one suspect product and at least one suspected reaction. If one is missing, the case is not yet valid for reporting and the team must ask for it. The details of what counts as identifiable are set in the applicable guidance and should be written into your procedure.
When does the reporting clock start?
In general terms, it starts on the day any employee or contracted partner first receives information that meets the minimum criteria. This is why an intake record with the exact first receipt date matters. The length of the clock depends on seriousness, expectedness and country, so check it against the regulation that applies.
What is the difference between seriousness and expectedness?
Seriousness describes the outcome, for example death, hospitalisation or a persistent disability. Expectedness describes whether the event is already listed in the reference safety information for the product. A serious and unexpected case usually has the strictest reporting rule.
How do I deal with duplicates?
Search on the data that identify the case, not on the reporter's reference alone, because partners and affiliates often use their own. If a match is found, add the new information as a follow-up version and keep a link to both sources. Document the matching rules so that processors apply them the same way.
Can I use this template for free?
Yes. Download it in Word or PDF and adapt it to your company. The company in the example is fictional.
Map your own version of this process.
Upload your SOP or describe the process. Processfix builds the map, simulates it and shows where the time goes. People review the results and decide.